FINALA64192AA2 FINALJuly 2008Beckman Coulter, Inc.4300 N. Harbor Blvd.Fullerton, CA 92835Error Recovery GuideLH 1500® Hematology Automation SystemHem
xTablesTables1.1 Error Codes,1-32.1 Outlet Unit Error Codes,2-14.1 Inlet Unit Error Codes,4-16.1 Connection Unit Error Codes,6-18.1 Stockyard Unit Err
A64192AA2 FINAL9-8Stockyard Unit ConveyorStockyard Unit Conveyor Pictures Figure 9.8 Stockyard Unit T Lane Top View
Figure 9.9 Stockyard Unit T Lane LH 1500 HEMATOLOGY AUTOMATION SYSTEM Stockyard Unit T Lane A641922AA2 9-9
A64192AA2 FINAL9-10Stockyard Unit ConveyorStockyard Unit Conveyor Pictures Sensor CodesThe sensor codes provide definitions of the alpha portion of th
A64192AA2 FINAL9-11Stockyard Unit ConveyorStockyard Unit Conveyor Pictures9Figure 9.11 Sotckyard Unit Top View Loading and Retrieivng Arms, Loading a
Figure 9.12 Stockyard Unit T Lane LH 1500 HEMATOLOGY AUTOMATION SYSTEM 3000 Tube Stockyard Top View 9-12 A641922AA2
A64192AA2 FINAL9-13Stockyard Unit ConveyorStockyard Unit Conveyor Pictures9Sensor CodesThe sensor codes provide definitions of the alpha portion of th
A64192AA2 FINAL9-14Stockyard Unit ConveyorStockyard Unit Conveyor Pictures Figure 9.14 300 mm Sorting Lane Top View
Figure 9.15 300 mm Sorting Lane LH 1500 HEMATOLOGY AUTOMATION SYSTEM 300 mm Sorting Lane A641922AA2 9-15
A64192AA2 FINAL9-16Stockyard Unit ConveyorStockyard Unit Conveyor Pictures Sensor CodesThe sensor codes provide definitions of the alpha portion of th
A64192AA2 FINAL9-17Stockyard Unit ConveyorStockyard Unit Conveyor Pictures9Figure 9.17 600 mm I Lane Top View
xiiFiguresFigures1.1 Cassette Handling Mechanism,1-91.2 LH Cassette Handling Mechanism,1-113.1 Outlet Unit,3-13.2 Outlet Unit Transfer Arm,3-23.3 Outl
Figure 9.18 600 mm I Lane LH 1500 HEMATOLOGY AUTOMATION SYSTEM 600 mm I Lane 9-18 A641922AA2
A64192AA2 FINAL9-19Stockyard Unit ConveyorStockyard Unit Conveyor Pictures9Sensor CodesThe sensor codes provide definitions of the alpha portion of th
A64192AA2 FINAL9-20Stockyard Unit ConveyorStockyard Unit Conveyor Pictures Figure 9.20 900 mm I Lane Top View
Figure 9.21 900 mm I Lane LH 1500 HEMATOLOGY AUTOMATION SYSTEM 900 mm I Lane A641922AA2 9-21
A64192AA2 FINAL9-22Stockyard Unit ConveyorStockyard Unit Conveyor Pictures Sensor CodesThe sensor codes provide definitions of the alpha portion of th
A64192AA2 FINALAbbreviations-1AbbreviationsAM — AC synchronous motorAS — Magnetic autoswitchBR — Bar-code readerBZ — Audible AlarmDM — DC MotorLP — La
A64192AA2 FINALAbbreviations-2Abbreviations
A64192AA2 FINALWarranty-1Beckman Coulter, Inc.Customer End User License AgreementThis Product contains software that is owned by Beckman Coulter, Inc.
A64192AA2 FINALWarranty-2Beckman Coulter, Inc. Customer End User License Agreement specifically agrees to the provision in writing. This agreement is
A64192AA2 FINALTrademarks-1TrademarksThe BECKMAN COULTER logo and COULTER are trademarks of Beckman Coulter, Inc.All other trademarks, service marks,
xiiiFigures9.13 300 mm Sorting Lane Side View,9-139.14 300 mm Sorting Lane Top View,9-149.15 mm Sorting Lane,9-159.16 600 mm I Lane Side View,9-169.17
© 2008 Beckman Coulter, Inc.All Rights Reservedwww.beckmancoulter.com
A64192AA2 FINAL1-1CHAPTER 1Error Recovery ProceduresGeneral Error RecoveryWhen a problem occurs at a unit, an audible alarm sounds and flashing warnin
A64192AA2 FINAL1-2Error Recovery ProceduresError Code Tables 8Locate the actual sensor in error on the unit. The sensor in error is labeled on the uni
A64192AA2 FINAL1-3Error Recovery ProceduresUnit Error Code Categories13. BR = Bar-code reader4. BZ = Audible alarm5. DM = DC motor6. LP = Lamp (keypad
A64192AA2 FINAL1-4Error Recovery ProceduresUnit Error Code Categories 4-xx Pulse Motor/AC Motor Pulse Motor/AC Motor Error(PMxx, SMxx or DMxx) Check
A64192AA2 FINAL1-5Error Recovery ProceduresError Recovery Shutdown1Error Recovery ShutdownThe Error Recovery Shutdown procedure takes the LH 1500 syst
A64192AA2 FINAL1-6Error Recovery ProceduresError Recovery Startup 9Press the red power OFF button on the Inlet Unit and turn off the automation line.N
A64192AA2 FINAL1-7Error Recovery ProceduresDisabling the LH Unit Block(s) from the Line Controller19Check for any Units that are Magenta colored. This
LH 1500® Hematology Automation SystemError Recovery GuidePN A64192AA2 (July 2008)Find us on the World Wide Web at: www.beckmancoulter.comBeckman Coult
A64192AA2 FINAL1-8Error Recovery ProceduresRemoving Cassettes from the Connection Unit 3Select <OK> to save changes or Select <Cancel> to
A64192AA2 FINAL1-9Error Recovery ProceduresRemoving Cassettes from the Connection Unit16Remove third cassette at position number one. At the same time
A64192AA2 FINAL1-10Error Recovery ProceduresLoading Cassettes in the Connection Unit Loading Cassettes in the Connection UnitProper loading of the cas
A64192AA2 FINAL1-11Error Recovery ProceduresSecondary Analysis Mode on the LH 1500 System1Figure 1.2 LH Cassette Handling MechanismSecondary Analysis
A64192AA2 FINAL1-12Error Recovery ProceduresSTAT-CASS Mode STAT-CASS ModeThe STAT-CASS mode (manual cassette mode) of operation allows processing of c
A64192AA2 FINAL1-13Error Recovery ProceduresBypassing the Connection Unit Table1Bypassing the Connection Unit TableIn the event of an unrecoverable er
A64192AA2 FINAL1-14Error Recovery ProceduresBypassing the Connection Unit Table
A64192AA2 FINAL2-1CHAPTER 2Outlet Unit Error Recovery CodesOutlet Unit Error Recovery CodesThe Outlet Unit Error Code Table 2.1 describes error messag
A64192AA2 FINAL2-2Outlet Unit Error Recovery CodesOutlet Unit Error Recovery Codes 1-06 SN06 Outlet rack #2 from the left not positioned correctly.Out
A64192AA2 FINAL2-3Outlet Unit Error Recovery CodesOutlet Unit Error Recovery Codes21-19 SN19 Proximity sensor did not detect a sample tube carrier ent
A64192AA2 FINALiiiRevision HistoryInitial Issue, 07/2008This document applies to the latest software listed and higher versions. When a subsequent sof
A64192AA2 FINAL2-4Outlet Unit Error Recovery CodesOutlet Unit Error Recovery Codes 2-07 SL07 Stopper error at Outlet waiting queue lane.Outlet Unit C
A64192AA2 FINAL2-5Outlet Unit Error Recovery CodesOutlet Unit Error Recovery Codes23-01 BR01 Failure of the bar-code reader BR01 to read. May have los
A64192AA2 FINAL2-6Outlet Unit Error Recovery CodesOutlet Unit Error Recovery Codes
A64192AA2 FINAL3-1CHAPTER 3Outlet UnitOutlet Unit PicturesThis chapter contains pictures of the Outlet Unit, Outlet Unit Transfer Arm, Outlet Unit Con
A64192AA2 FINAL3-2Outlet UnitOutlet Unit Pictures Figure 3.2 Outlet Unit Transfer ArmFigure 3.3 Outlet Unit Conveyor
Figure3.4 Outlet Unit Sensor Cods LH 1500 HEMATOLOGY AUTOMATION SYSTEM Outlet Unit A641922AA2 3-3
A64192AA2 FINAL3-4Outlet UnitSensor Codes Sensor CodesThe sensor codes provide definitions of the alpha portion of the codes found in the Sensor colum
A64192AA2 FINAL4-1CHAPTER 4Inlet Unit Error RecoveryInlet Unit Error Recovery CodesThe Inlet Unit Error Code Table 4.1 describes error messages genera
A64192AA2 FINAL4-2Inlet Unit Error RecoveryInlet Unit Error Recovery Codes 1-09 SN09 Sample tube carrier failed to arrive in the time allotted at the
A64192AA2 FINAL4-3Inlet Unit Error RecoveryInlet Unit Error Recovery Codes42-05 SL05 Stopper error before the Inlet sample tube carrier loading positi
A64192AA2 FINALivRevision History
A64192AA2 FINAL4-4Inlet Unit Error RecoveryInlet Unit Error Recovery Codes
A64192AA2 FINAL5-1CHAPTER 5Inlet UnitInlet Unit PicturesThis chapter contains pictures of the Inlet Unit, Inlet Unit Transfer Arm, Inlet Unit Conveyor
A64192AA2 FINAL5-2Inlet UnitInlet Unit Pictures Figure 5.2 Inlet Unit Transfer ArmFigure 5.3 Inlet Unit Conveyor
Figure 5.4 Inlet Unit Sensor Codes LH 1500 HEMATOLOGY AUTOMATION SYSTEM Inlet Unit A641922AA2 5-3
A64192AA2 FINAL5-4Inlet UnitInlet Unit Pictures Sensor CodesThe sensor codes provide definitions of the alpha portion of the codes found in the Sensor
A64192AA2 FINAL6-1CHAPTER 6Connection UnitConnection Unit Error RecoveryThe Connection Unit Error Code Table 6.1 describes error messages generated by
A64192AA2 FINAL6-2Connection UnitConnection Unit Error Recovery 1-03 SN03 Obstruction or hardware error at the upper limit sensor on the Cassette Load
A64192AA2 FINAL6-3Connection UnitConnection Unit Error Recovery61-22 SN22 Sample Tube Loading Arm at the near home position did not initialize due to
A64192AA2 FINAL6-4Connection UnitConnection Unit Error Recovery 1-25 SN25 Scenario:1. Unanalyzed cassette may be in cassette load position #5 of the s
A64192AA2 FINAL6-5Connection UnitConnection Unit Error Recovery61-28 SN28 One of two limit sensors associated with cylinder SL25. Unload Cassette Shut
A64192AA2 FINALvSafety NoticeRead all product manuals and consult with Beckman Coulter-trained personnel before attempting to operate instrument. Do n
A64192AA2 FINAL6-6Connection UnitConnection Unit Error Recovery 1-33 SN33 Scenario:1. Leading edge of cassette was not detected by sensor SN33 at cass
A64192AA2 FINAL6-7Connection UnitConnection Unit Error Recovery61-37 SN37 Scenarios:1. Cassette was not detected inside the Load Shuttle cassette posi
A64192AA2 FINAL6-8Connection UnitConnection Unit Error Recovery 1-41 SN41 Scenarios:1. Fiber optic sensor did not detect a sample tube at Connection U
A64192AA2 FINAL6-9Connection UnitConnection Unit Error Recovery61-47 SN47 Safety cover over the Right-side Cassette Loading Arm was off or not properl
A64192AA2 FINAL6-10Connection UnitConnection Unit Error Recovery 1-62 SN62 Sample tube carrier error in the area in front of the Conveyor Lane bar-cod
A64192AA2 FINAL6-11Connection UnitConnection Unit Error Recovery61-72 SN72 One of two limit sensors for the Conveyor Loading Arm cylinder SL72.Connect
A64192AA2 FINAL6-12Connection UnitConnection Unit Error Recovery 2-03 SL03 During its operation Cassette Loading Arm cylinder SL03 did not swing up/do
A64192AA2 FINAL6-13Connection UnitConnection Unit Error Recovery62-21 SL21 Cassette jam was detected in cassette load position #5. Cassette could be j
A64192AA2 FINAL6-14Connection UnitConnection Unit Error Recovery 2-23 SL23 Stopped cassette error at cassette position #6. Cassette could be jammed.Co
A64192AA2 FINAL6-15Connection UnitConnection Unit Error Recovery62-26 SL26 Cassette Ejector cylinder SL26 did not fully extend and misses activating t
A64192AA2 FINALviSafety NoticeAlerts for Warning and Caution WARNINGRisk of operator injury if: • All doors covers and panels are not closed and secur
A64192AA2 FINAL6-16Connection UnitConnection Unit Error Recovery 2-41 SL41 Sample Tube Loading Arm cylinder did not extend / retract properly and miss
A64192AA2 FINAL6-17Connection UnitConnection Unit Error Recovery62-45 SL45 Sample Tube Unloading Arm cylinder SL45 did not fully extend / retract and
A64192AA2 FINAL6-18Connection UnitConnection Unit Error Recovery 2-50 SL50 Vertical Unload Elevator cylinder SL50 did not fully extend / retract and m
A64192AA2 FINAL6-19Connection UnitConnection Unit Error Recovery62-65 SL65 Stopper error at Conveyor Loading Arm point "a".Connection Unit C
A64192AA2 FINAL6-20Connection UnitConnection Unit Error Recovery 2-71 SL71 Conveyor Loading Arm rotary cylinder SL71 error while swinging between the
A64192AA2 FINAL6-21Connection UnitConnection Unit Error Recovery63-02 BR02 Failure of the Bar-code reader BR02. May have lost programming.Connection U
A64192AA2 FINAL6-22Connection UnitConnection Unit Error Recovery 9-01 AM01 AC Synchronous Motor Failure while driving the Cassette Loading Arm up or d
A64192AA2 FINAL7-1CHAPTER 7Connection Unit ConveyorConnection Unit Conveyor PicturesThis chapter contains pictures of the Connection Unit Conveyor, Co
A64192AA2 FINAL7-2Connection Unit ConveyorConnection Unit Conveyor Pictures Figure 7.2 Connection Unit Conveyor Top View
Figure 7.3 Connection Unit Conveyor LH 1500 HEMATOLOGY AUTOMATION SYSTEM Connection Unit Conveyor A641922AA2 7-3
viiContentsRevision History, iiiSafety Notice,vCHAPTER 1: Error Recovery Procedures,1-1General Error Recovery,1-1Error Code Tables,1-2Sensor Codes,1-2
A64192AA2 FINAL7-4Connection Unit ConveyorConnection Unit Conveyor Pictures Sensor CodesThe sensor codes provide definitions of the alpha portion of t
A64192AA2 FINAL7-5Connection Unit ConveyorConnection Unit Conveyor Pictures7Figure 7.5 Connection Unit Loading and Unloading Arms
Figure 7.6 Connection Unit Loading and Unloading Arms LH 1500 HEMATOLOGY AUTOMATION SYSTEM Connection Unit Loading and Unloading Arms 7-6 A6
A64192AA2 FINAL7-7Connection Unit ConveyorConnection Unit Conveyor Pictures7Sensor Codes:The sensor codes provide definitions of the alpha portion of
A64192AA2 FINAL7-8Connection Unit ConveyorConnection Unit Conveyor Pictures Figure 7.8 Connection Unit Side View
Figure 7.9 Connection Unit Side View LH 1500 HEMATOLOGY AUTOMATION SYSTEM Connection Unit Side View A641922AA2 7-9
A64192AA2 FINAL7-10Connection Unit ConveyorConnection Unit Conveyor Pictures Sensor Codes:The sensor codes provide definitions of the alpha portion of
A64192AA2 FINAL7-11Connection Unit ConveyorConnection Unit Conveyor Pictures7Figure 7.11 Connection Unit Top View
Figure 7.12 Connection Unit Top Diagram LH 1500 HEMATOLOGY AUTOMATION SYSTEM Connection Unit Top View 7-12 A641922AA2
A64192AA2 FINAL7-13Connection Unit ConveyorConnection Unit Conveyor Pictures7Sensor Codes:The sensor codes provide definitions of the alpha portion of
viiiContentsCHAPTER 5: Inlet Unit,5-1Inlet Unit Pictures,5-1Inlet Unit Sensor Codes,5-3Sensor Codes,5-4CHAPTER 6: Connection Unit,6-1Connection Unit E
A64192AA2 FINAL7-14Connection Unit ConveyorConnection Unit Conveyor Pictures
A64192AA2 FINAL8-1CHAPTER 8 Stockyard UnitStockyard Unit Error RecoveryThe Stockyard Unit Error Code Table 8.1 describes error messages generated by t
A64192AA2 FINAL8-2Stockyard UnitStockyard Unit Error Recovery 0-21 BZ21 Stockyard bar-code reader error at BR02.Stockyard UnitConveyorD-4 1. Ensure th
A64192AA2 FINAL8-3Stockyard UnitStockyard Unit Error Recovery81-40 SN40 Sample tube carrier error before the Stockyard bar-code reader BR01.Stockyard
A64192AA2 FINAL8-4Stockyard UnitStockyard Unit Error Recovery 1-51 SN51 Proximity sensor did not detect the expected sample tube carrier after it pass
A64192AA2 FINAL8-5Stockyard UnitStockyard Unit Error Recovery81-63 SN63 Proximity sensor did not detect a sample tube carrier on return lane.Stockyard
A64192AA2 FINAL8-6Stockyard UnitStockyard Unit Error Recovery 2-06 SL06 Rotating cylinder error on the Stockyard Loading Elevator.3000 Tube StockyardT
A64192AA2 FINAL8-7Stockyard UnitStockyard Unit Error Recovery82-41 SL41 Stopper error before the Stockyard bar-code reader BR01.StockyardUnit Conveyor
A64192AA2 FINAL8-8Stockyard UnitStockyard Unit Error Recovery 2-55 SL55 Stopper error at the T-Lane before sorting position.StockyardUnit T LaneC-3 1.
A64192AA2 FINAL8-9Stockyard UnitStockyard Unit Error Recovery82-63 SL63 Stopper error at the H-Lane empty sample tube carrier lane. StockyardUnit H
ixContentsSensor Codes,9-22Abbreviations, Abbreviations-1Beckman Coulter, Inc.Customer End User License Agreement,Warranty-1Trademarks,Trademarks-1
A64192AA2 FINAL8-10Stockyard UnitStockyard Unit Error Recovery 4-02 SM02 Failure to move the Stockyard Transfer Arm on the first level in the Y-axis d
A64192AA2 FINAL8-11Stockyard UnitStockyard Unit Error Recovery84-06 SM06 Failure to move the Stockyard Transfer Arm on the second level in the Y-axis
A64192AA2 FINAL8-12Stockyard UnitStockyard Unit Error Recovery 7-22 AS22 Stockyard Internal Transfer Arm gripper on the second level failed to pick up
A64192AA2 FINAL9-1CHAPTER 9Stockyard Unit ConveyorStockyard Unit Conveyor PicturesFigure 9.1 Stockyard Unit Overall Rear View
A64192AA2 FINAL9-2Stockyard Unit ConveyorStockyard Unit Conveyor Pictures Figure 9.2 Stockyard Unit Conveyor Top View
Figure 9.3 Connection Unit Top Diagram LH 1500 HEMATOLOGY AUTOMATION SYSTEM Stockyard Unit Conveyor A641922AA2 9-3
A64192AA2 FINAL9-4Stockyard Unit ConveyorStockyard Unit Conveyor Pictures Sensor CodesThe sensor codes provide definitions of the alpha portion of the
A64192AA2 FINAL9-5Stockyard Unit ConveyorStockyard Unit Conveyor Pictures9Figure 9.5 Stockyard Unit H Lane Top View
Figure 9.6 Stockyard Unit H Lane LH 1500 HEMATOLOGY AUTOMATION SYSTEM Stockyard Unit H Lane 9-6 A641922AA2
A64192AA2 FINAL9-7Stockyard Unit ConveyorStockyard Unit Conveyor Pictures9Sensor CodesThe sensor codes provide definitions of the alpha portion of the
Commentaires sur ces manuels