Code Alarm ca6153 Guide d'installation Page 14

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 56
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 13
14 ca6153 revA
4 Pin Alternate Output Harness
1 LT GREEN/BLACK FACTORY DISARM /
PULSE BEFORE START ( - )
This wire will supply a ( - ) 200mA pulse both upon disarming the system and
when the remote start feature is activated. Locate the factory perimeter alarm
disarm wire from the key cylinder inside the drivers door.
Verification: This wire registers ground if the key is turned to the unlock
position in the driver’s door cylinder.
This output can be configured in option programming.
2 LT BLUE FACTORY ARM /
PULSE AFTER START ( - )
This wire will supply a ( - ) 200mA pulse both upon arming the system and upon
successful completion of the remote start activation sequence and is typically
used to re-lock the vehicle’s doors upon remote start if necessary.
This output can be configured in option programming.
4 BLACK/YELLOW PULSE DURING CRANK ( - )
Locate the vehicle’s second starter (crank) wire at the ignition switch. (if
equipped)
Verification: This wire registers voltage
only in the start (crank) position of
the ignition switch.
This output can be configured in option programming.
3 GREEN/WHITE PULSE AFTER SHUTDOWN ( - )
This wire will supply a ( - ) 200mA pulse after the remote start shuts down. This
is typically used to re-lock the vehicle’s doors if they unlock upon remote start
shutdown. It can also be used to pulse a door pin-switch wire to prevent the
vehicle’s accessories from remaining on after remote start shutdown.
This output can be configured in option programming.