112009 Audiovox Electronics Corporation. All rights reserved.
8 Pin Input Harness
5 LT GREEN/BLACK FACTORY DISARM /
PULSE BEFORE START ( - )
This wire will supply a ( - ) 500mA pulse both upon disarming the system and when
the remote start feature is activated. Locate the factory perimeter alarm disarm
wire from the key cylinder inside the drivers door.
Verification: This wire registers ground if the key is turned to the unlock
position in the driver’s door cylinder.
Connect the LIGHT GREEN/BLACK wire to the factory alarm disarm wire.
3 VIOLET/BLACK AUX 1
This wire provides a ( - ) 500mA output capable of driving relays. For Control of
optional accessories (i.e. Power Window/Sunroof, etc.).
To activate refer to the transmitter button configuration chart. Please refer to the
selectable options for timing.
4 RED/WHITE TRUNK RELEASE OUTPUT ( - )
Locate the vehicle’s trunk release wire at the trunk release switch.
Verification: This wire will register either positive voltage or ground when the trunk
release is activated.
This is a low current output, 500mA.
6 ORANGE GROUND WHEN ARMED OUTPUT ( - )
This wire will have a continuous ( - ) 500mA output when the system is Armed. This
wire is typically used for controlling window modules or additional sensors.
1 BLUE/WHITE INSTANT TRIGGER INPUT ( - )
This wire is a GROUND input for an external sensor or secondary pin switch.
Verification: This wire when connected will trigger the security system.